Technical specifications
Specifications ZR 200-355 VSD⁺ Pack
Model | Working pressure | Free Air Delivery (1) | Installed motor power | Noise level (2) | Weight | ||
bar(e) | l/s | m³/min | kW | dB(A) | kg | ||
ZR 200 VSD⁺ 10.4 | Minimum | 4 | 257 – 650 | 15.4 – 39 | 200 | 73 | 5580 |
ZR 200 VSD⁺ 10.4 | Effective | 7 | 255 – 611 | 15.3 – 36.6 | 200 | 73 | 5580 |
ZR 200 VSD⁺ 10.4 | Maximum | 10.4 | 251 – 480 | 15.1 – 28.8 | 200 | 73 | 5580 |
ZR 250 VSD⁺ 10.4 | Minimum | 4 | 257 – 810 | 15.4 – 48.6 | 250 | 74 | 5580 |
ZR 250 VSD⁺ 10.4 | Effective | 7 | 255 – 767 | 15.3 – 46 | 250 | 74 | 5580 |
ZR 250 VSD⁺ 10.4 | Maximum | 10.4 | 251 – 620 | 15.1 – 37.2 | 250 | 74 | 5580 |
ZR 315 VSD⁺ 10.4 | Minimum | 4 | 257 – 955 | 15.4 – 57.3 | 315 | 74 | 5580 |
ZR 315 VSD⁺ 10.4 | Effective | 7 | 255 – 955 | 15.3 – 57.3 | 315 | 74 | 5580 |
ZR 315 VSD⁺ 10.4 | Maximum | 10.4 | 251 – 796 | 15.1 – 47.8 | 315 | 74 | 5580 |
ZR 355 VSD⁺ 8.6 | Minimum | 4 | 257 – 1063 | 15.4 – 63.8 | 355 | 74 | 5580 |
ZR 355 VSD⁺ 8.6 | Effective | 7 | 255 – 1063 | 15.3 – 63.8 | 355 | 74 | 5580 |
ZR 355 VSD⁺ 8.6 | Maximum | 8.6 | 254 – 989 | 15.2 – 59.3 | 355 | 74 | 5580 |
ZR 355 VSD⁺ 10.4 | Minimum | 4 | 257 – 988 | 15.4 – 59.3 | 355 | 74 | 5580 |
ZR 355 VSD⁺ 10.4 | Effective | 7 | 255 – 988 | 15.3 – 59.3 | 355 | 74 | 5580 |
ZR 355 VSD⁺ 10.4 | Maximum | 10.4 | 251 – 902 | 15.1 – 54.1 | 355 | 74 | 5580 |
Dimensions ZR 200-355 VSD⁺ Pack
Model | Length | Width | Height |
Model | mm | ||
ZR 200-355 VSD⁺ Pack | 3044 | 1760 | 2150 |
ImperialMetric
Units
Working pressure bar(e)
4
7
10.4
8.6
Installed motor power kW
200
250
315
355
(1) Unit performance measured according to ISO 1217, Annex E, Edition 4 (2009).
Reference conditions:
– Relative humidity 0%
– Absolute inlet pressure 1 bar (14.5 psi)
– Intake air temperature 20°C (68°F)
Free Air Delivery (FAD) is measured at effective working pressure.
(2) A-weighted emission sound pressure level at the work station (LpWSAd). Measured according to ISO 2151:2008 using ISO 9614-2 (sound intensity scanning method). The added correction factor (+/- 3 db(A)) is the total uncertainty value (KpAd) conform with the test code.