Technical specifications
Specifications ZR 200-355 VSD⁺ FF (iMDG)
Model | Working pressure | Free Air Delivery (1) | Installed motor power | Noise level (2) | Weight | ||
bar(e) | l/s | m³/min | kW | dB(A) | kg | ||
ZR 200 VSD⁺ 10.4 | Minimum | 6 | 255-643 | 15.3 – 38.6 | 200 | 73 |
Pack: 5120 iMDG dryer: 2530 |
ZR 200 VSD⁺ 10.4 | Effective | 7 | 255-606 | 15.3 – 36.4 | 200 | 73 |
Pack: 5120 iMDG dryer: 2530 |
ZR 200 VSD⁺ 10.4 | Maximum | 10.4 | 251-477 | 15.1 – 28.6 | 200 | 73 |
Pack: 5120 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Minimum | 6 | 255-797 | 15.3 – 47.8 | 250 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Effective | 7 | 255-756 | 15.3 – 45.4 | 250 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Maximum | 10.4 | 251-614 | 15.1 – 36.8 | 250 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Minimum | 6 | 255-937 | 15.3 – 56.2 | 315 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Effective | 7 | 255-937 | 15.3 – 56.2 | 315 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Maximum | 10.4 | 251-786 | 15.1 – 47.2 | 315 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Minimum | 6 | 255 – 1041 | 15.3 – 62.5 | 355 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Effective | 7 | 255 – 1041 | 15.3 – 62.4 | 355 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Maximum | 8.6 | 254 – 970 | 15.2 – 58.2 | 355 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Minimum | 6 | 255 – 969 | 15.3 – 58.1 | 355 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Effective | 7 | 255 – 969 | 15.3 – 58.1 | 355 | 74 |
Pack: 5120 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Maximum | 10.4 | 251 – 888 | 15.1 – 53.3 | 355 | 74 |
Pack: 5120 iMDG dryer: 2530 |
Dimensions ZR 200-355 VSD⁺ FF (iMDG)
Model | Length | Width | Height |
Model | mm | ||
ZR 200-355 VSD⁺ FF (iMDG) | 5651 | 1927 | 2150 |
ImperialMetric
Units
Working pressure bar(e)
6
7
10.4
8.6
Installed motor power kW
200
250
315
355
(1) Unit performance measured according to ISO 1217, Annex E, Edition 4 (2009).
Reference conditions:
– Relative humidity 0%
– Absolute inlet pressure 1 bar (14.5 psi)
– Intake air temperature 20°C (68°F)
Free Air Delivery (FAD) is measured at effective working pressure.
(2) A-weighted emission sound pressure level at the work station (LpWSAd). Measured according to ISO 2151:2008 using ISO 9614-2 (sound intensity scanning method). The added correction factor (+/- 3 db(A)) is the total uncertainty value (KpAd) conform with the test code.