| General | IP grade | IP54 |
| Cooler Version | Dry cooler | V |
| Adiabatic cooler | V |
| Air filter screens | Aluminium Air filter | opt |
| Installation | Lifting with ropes + spreader beam | ⚫ |
| Electrical | 400V/3ph 50Hz IEC | V |
| 460V/3ph 60Hz UL 508A | V |
| Energy meter | opt |
| Control | Controller type | Electronikon Mk5S |
| 4,3″ touchscreen | ⚫ |
| Text on display in local language (english, italiano, deutsch, slovensko, espanol, francais) | ⚫ |
| Day and week scheduler | ⚫ |
| Service timer | ⚫ |
| Dynamic set-point | ⚫ |
| Safety | Thermal-magnetic circuit breakers protection on fans and pumps | ⚫ |
| Flow switch | opt |
| Winter protection: auto-ON of the pump with low ambient temperature (software function) | ⚫ |
| Remote temperature sensor | opt |
| System integration | Remote ON-OFF | ⚫ |
| Single free contact for warning & shut down alarm | ⚫ |
| Remote setpoint + Temperature transmission (4..20mA) | opt |
| Modbus RTU – RS485 | accessory |
| CANbus | accessory |
| Profibus | accessory |
| Profinet | accessory |
| TCP | accessory |
| Ehernet IP | accessory |
| Remote control panel | accessory |
| Connectivity | Smartlink connectivity incl modem (4G), incl ‘service’ license | ⚫ |
| Smartlink UPTIME license | opt |
| Hydronics | No Pump | ⚫ |
| Circulation Pump stainless steel (cooling water manifold included) | V |
| Standby Circulation Pump stainless steel (cooling water manifold included) | V |
| Cooling water manifold | opt |
| Manual filling system and drain | ⚫ |
| Automatic filling with: city water line filter, pressure reducer | opt |
| Expansion vessels 24l | opt |
| Expansion vessels 80l | opt |
| Water pressure gauge (only if pump is included) | ⚫ |
| Grooved water connections: 3″ | ⚫ | – |
| Grooved water connections: 4″ | – | ⚫ |
| Flanged connection: UNI flanges | opt |
| Flanged connection: ANSI flanges | opt |
| Counterflanges | opt |
| External manual by-pass (only if manifold is included) | ⚫ |
| Adiabatic system | Descaling Filter | opt |
| Fan | AC fans | ⚫ |
| Variable speed control for fans – phase cut controller | V |
| Variable speed control for fans – VFD (mounted inside cabinet) | V | – |
| Variable speed control for fans – VFD (mounted outside cabinet with metal protection) | – | V |
| Heat exchanger | Aluminum fins/copper tube coil | ⚫ |
| Packaging | Plastic wrap protection | ⚫ |
| Wooden base | opt |
| Wooden case (close box) | opt |
|
| ⚫ | Standard |
| V | Version: select the correct equipment material number |
| opt | Optional accessory |
| – | Not available |