ZL 1–4 (ohne Starter)
Lieferumfang
Standard scope of supply | ZL 1 VSD | ZL 1 | ZL 2 VSD | ZL 2 | ZL 3 VSD | ZL 3 | ZL 4 VSD | ZL 4 | |
Air circuit | Air inlet filter | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Inlet pulsation damper | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Oil-free lobe element | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Start-up valve | – | – | ✓* | ✓* | ✓ | ✓ | ✓ | ✓ | |
Safety valve | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Check valve | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Discharge pulsation damper | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Outlet compensator (stainless steel) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Outlet air flange DIN or ANSI | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Oil circuit | Supplied oil-filled | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Splash lubricated element bearings & gears | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Motor | IE3 induction motor, TEFC IP55 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
IE4 75-90 kW | – | – | – | – | – | – | ✓ | ✓ | |
Mechanical | Pulley & belt | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Automatic belt tensioning system | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Bodywork | Sound attenuating canopy | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Package vibration isolators | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Base frame with forklift slots | – | – | – | – | ✓ | ✓ | ✓ | ✓ |
ZL 1–2 (mit Starter VSD)
Standard scope of supply | ZL 1 VSD | ZL 1 | ZL 2 VSD | ZL 2 | |||||
Choice between: | Mechanical | Elektronikon® | Mechanical | Elektronikon® | Mechanical | Elektronikon® | Mechanical | Elektronikon® | |
Monitoring and control | Pressure gauge and filter indicator | ✓ | – | ✓ | – | ✓ | – | ✓ | – |
VSD inverter, EMC – and RFI filter, TT/TN net | – | ✓ | – | – | – | ✓ | – | – | |
Y/D starter | – | – | – | ✓ | – | – | – | ✓ | |
Sensors discharge pressure & temperature | – | ✓ | – | ✓ | – | ✓ | – | ✓ | |
SMARTLINK | – | ✓ | – | ✓ | – | ✓ | – | ✓ | |
Flow control via 4-20 mA (external source) | – | ✓ | – | – | – | ✓ | – | – | |
LAN or internet control/monitoring | – | ✓ | – | ✓ | – | ✓ | – | ✓ |
ZL 3–4 (mit Starter VSD)
Standard scope of supply | ZL 3 VSD | ZL 3 | ZL 4 VSD | ZL 4 | |||||
Choice between: | Mechanical | Elektronikon® | Mechanical | Elektronikon® | Mechanical | Elektronikon® | Mechanical | Elektronikon® | |
Monitoring and control | Pressure gauge and filter indicator | ✓ | – | ✓ | – | ✓ | – | ✓ | – |
VSD inverter, EMC – and RFI filter, TT/TN net | – | ✓ | – | – | – | ✓ | – | – | |
Y/D starter | – | – | – | ✓ | – | – | – | ✓ | |
Sensors discharge pressure & temperature | – | ✓ | – | ✓ | – | ✓ | – | ✓ | |
SMARTLINK | – | ✓ | – | ✓ | – | ✓ | – | ✓ | |
Flow control via 4-20 mA (external source) | – | ✓ | – | – | – | ✓ | – | – | |
LAN or internet control/monitoring | – | ✓ | – | ✓ | – | ✓ | – | ✓ |
Optionen
Testzertifikat
SMARTLINK
Steuerung Elektronikon Mk5
Flansch gemäß DIN/ANSI
Volloptions-Motor
Riemenabdeckung in der Haube
Outdoor-Haube
Funkenfänger (ATEX-zertifiziert)
UL-Zulassung
Holzkiste für Transport
Optionen sind für alle Rahmengrößen verfügbar.